The Glycount portable liquid particle counter that we offer for rent measures, stores, and measures glycol fluid cleanliness in a fraction of the time needed for traditional analysis methods. This new portable instrument analyzes glycol fluids and coolants in bottle sampling or on-line modes.
Downloads
Target ISO Cleanliness Codes Understanding ISO Codes- Stop paying someone else for data - fast Results in the field - Sample and report particle counts in less than a minute.
- No training or instrument expertise required - The Glycount is so easy to use, there is no training required. Simply turn the Glycount on and get your data now.
- Manage all your applications for any fluid and reporting standards - Compatible with Oceanic HW540, Transaqua HT, Pelagic 100 and many other glycol fluids. Bottle or on-line sampling up to 50 cST and 8 channels of liquid particle counting data. Supports ISO 4406, NAS 1638 and user-defined tests to both MTD, ACFTD, and ISO11171 particle counting standards.
- Accuracy, reliability and quality - Determine your machines operating condition with lab results in the field, the Glycount liquid particle counter offers point-of-use lab accuracy in the field.
- Number of Channels
- 8
- Flow Rate
- 50 mL/min standard
- Calibration
- PSL Calibration and ISO-MTD in glycol
- Counting Efficiency
- Meets JIS B9925:1997
- Concentration Limit
- 20,000 particles/mL at 5% coincidence loss (per ISO 11171)
- 30,000 particles/mL at 10% coincidence
- Fluid Temperature Range
- 0 to 65°C at 25°C ambient (32 to 150°F at 77°F ambient)
- Measured Fluid Temperature
- 0 to 65°C, ±0.5°C (32 to 150°F, ±0.9°F)
- Viscosity Range
- 2 to 50 cSt
- Wetted Materials
- Brass, stainless steel, sapphire, PTFE, and Aflas®
- Cleanliness Classification
- SAE AS 4059, NAS 1638, ISO 4406-1991, ISO 4406.2-1999
- Data Storage
- 500 Sample Records
- Dimensions
- 17.8 D x 33.0 W x 35.6 H cm (7 x 12.5 x 14 inches)
- Weight
- 9.5 kg (21 lbs)
- Serial Communication
- RS-232
- Bottle Operation
- Sample Volume: 3 runs (averaged) of 5, 10 or 20 mL/run, programmable
- Purge Volume: 15 to 30 mL, programmable
- Pressure Cartridge: CO2, replaceable, rechargeable
- Operating Time: 60 samples per cartridge (120 mL sample bottle)
- Shop Air: 90 to 110 psi (6.2 to 7.6 bar) clean, dry
- On-line Operation
- Sampler Volume: 3 runs (averaged) of 5, 10, 20, 50 or 100 mL/run, programmable
- Purge Volume: 25 to 999 mL, programmable
- Fluid Pressure: 100 to 3000 psi (7 to 207 bar)
- Power
- +24 VDC @ 2A maximum
- AC/Battery Adapter Universal
- 100 to 240 VAC, 50 to 60 Hz, 60 W - Battery Nickel-Metal Hydride
- Battery Operating Time
- 100 samples or 4 hours continuous
- Battery Recharge Time
- 2.5 hours
- Ambient Operating Conditions
- 0 to 50°C (32 to 122°F), 20 to 85% relative humidity, non-condensing
- GlyCount Storage Conditions
- -40 to 70°C (-40 to 158°F), up to 98% relative humidity, non-condensing