Varnish Treatment for Pharmaceutical Company

Apr 1, 2025 | Contamination, Fuel & Oil, Hydraulic & Lubrication, Industrial Facility, Oil Quality & Purification

  1. Home
  2. Contamination
  3. Varnish Treatment for Pharmaceutical Company

A large pharmaceutical company was having issues with the hydraulic system on a critical piece of testing equipment. The customer was experiencing stiction issues with bearings. Their oil analysis revealed that they had varnish present within the oil. The MPC showed a result of 56. The UC showed 4. To prevent downtime and costly service, we proposed using a 3% treatment dose of Decon from Fluitec. Previous service on this same unit had cost the customer roughly $1 Million dollars and took approximately 8 months for the equipment to be repaired.

The customer went with our recommendation and added the Decon to their reservoir in the beginning of January. Customer testing of the oil in the beginning of February indicated that the varnish situation was improving. The MPC showed 8 and the UC showed 1. Visual inspection of the equipment by representatives of the equipment manufacturer indicated that the plated varnish had been removed from the equipment surfaces. The customer will continue to monitor the oil but does not expect varnish to be a further issue. The customer will continue with their regular offline filtering of the reservoir using a PFP Drum Top Filter system to keep the oil within their targeted ISO Cleanliness Code of 13/12/7.

Find out how PFP can help your business prevent costly downtime… give us a call! 

Contact an Expert

Need assistance? PFP will help you solve your industrial filtration challenges.

1-888-679-6645 / sales@pfpusa.com

Related Blog Posts

Case Study: Emergency Lube Oil Dehydration at East Coast Refinery

Case Study: Emergency Lube Oil Dehydration at East Coast Refinery

Lube Oil Contamination SolutionsThis case study explains how PFP executed a same-day deployment of a 50 GPM dehydrator to address a major water ingression event. Recently, we were contacted by an east coast refinery experiencing a sudden & significant water...

How Heater Skids Improve High Velocity Flushing Performance

How Heater Skids Improve High Velocity Flushing Performance

If your system can’t reach turbulent flow, viscosity may be the issue. Heater skids reduce fluid thickness and help your flushing setup perform as intended.High velocity flushing is one of the most effective methods for removing contamination from piping systems,...

How Often Should Generator Fuel Be Tested?

How Often Should Generator Fuel Be Tested?

Drop us a follow on social media!TL;DR - Generator fuel should be tested at least once per year to check for water, microbial growth, and particulate contamination. Critical facilities like hospitals and data centers often test every 6 months or quarterly to ensure...

Follow us on social media!

Contact an Expert

Need assistance? PFP will help you solve your industrial filtration challenges.

1-888-679-6645 / sales@pfpusa.com

Want the most up to date information from PFP?

Sign up for our E-mail newsletter!